B-65285EN/03 TROUBLESHOOTING 3.TROUBLESHOOTING AND ACTION
- 129 -
3.4.37 Alarm Code 76
This alarm can be issued only when Dual Check Safety is in use.
The spindle safety function has not been executed.
If the alarm occurs, replace the SPM control printed-circuit board.
3.4.38 Alarm Code 77
This alarm can be issued only when Dual Check Safety is in use.
The result of the spindle amplifier axis number check does not match
the result of the CNC axis number check.
If the alarm occurs, replace the CPU card in the CNC or the SPM
control printed-circuit board.
3.4.39 Alarm Code 78
This alarm can be issued only when Dual Check Safety is in use.
The result of spindle amplifier safety parameter check does not match
the result of the CNC safety parameter check.
If the alarm occurs, replace the CPU card in the CNC or the SPM
control printed-circuit board.
3.4.40 Alarm Code 79
This alarm can be issued only when Dual Check Safety is in use.
An abnormal operation was detected in the initial test.
When this alarm is issued, Replace the SPM or SPM control printed
circuit board.