3.TROUBLESHOOTING AND ACTION TROUBLESHOOTING B-65285EN/03
- 112 -
3.4 SPINDLE AMPLIFIER MODULE
If an alarm occurs in the spindle amplifier module, the ALM LED
lights red in the STATUS display, and the two-digit 7-segment LEDs
indicate the alarm code.
The ALM LED
lights red.
Alarm code 01, 02 or above is indicated.
status
3.4.1 Alarm Code 01
The inside temperature of the motor is higher than the specified
temperature.
(1) If this alarm is issued during cutting (the motor temperature is
high)
(a) Check the cooling state of the motor.
<1> If the cooling fan of the spindle motor is stopped, check
the power supply of the cooling fan. If the cooling fan is
still inoperative, replace it with a new one.
<2> When a liquid-cooled motor is used, check the cooling
system.
<3> When the ambient temperature of the spindle motor is
higher than the specified temperature, lower the
ambient temperature to satisfy the specification.
(b) Recheck the cutting conditions.
(2) If this alarm is issued under a light load (the motor temperature is
high)
(a) When the frequency of acceleration/deceleration is too high
Set such a use condition that the average including output at
acceleration/deceleration does not exceed the continuous
rating.
(b) The parameters specific to the motor are not correctly.
Referring to "FANUC AC SPINDLE MOTOR αi series
Parameter Manual (B-65280EN)," check the motor-specific
parameters.
(3) If this alarm is issued when the motor temperature is low
(a) The spindle motor feedback cable is faulty.
Replace the cable.