4.CONFIRMATION OF THE OPERATION START-UP PROCEDURE B-65285EN/03
- 44 -
4.3.5.3 Check terminal output signals
(1) αi series
Check terminal Signal name Check terminal Signal name
LM Load meter signal PA1 Phase A sine wave signal 1
SM Speedometer signal PB1 Phase B sine wave signal 1
CH1
Analog output for internal data
observation
(Phase U current: IU)
PS1 Phase Z sine wave signal 1
CH2
Analog output for internal data
observation
(Motor speed TSA: 1638 min
-1
/V)
PA2 Phase A sine wave signal 2 (TYPE B)
CH1D Output for internal data bit observation PB2 Phase B sine wave signal 2 (TYPE B)
CH2D Output for internal data bit observation PS2 Phase Z sine wave signal 2 (TYPE B)
VRM Disuse PA3 Disuse
LSA1 Disuse PB3 Disuse
EXTSC1 External one-rotation signal (main) PA4 Disuse
LSA2 Disuse PB4 Disuse
EXTSC2 Disuse OVR2 Analog override command
PAD
Phase A of position coder signal output
(TYPE B)
15V Disuse
PBD
Phase B of position coder signal output
(TYPE B)
5V +5 VDC power check
PSD
Phase Z of position coder signal output
(TYPE B)
-15V Disuse
GND 0 V
(2) αCi series
Check terminal Signal name Check terminal Signal name
LM
Speedometer signal (This can be
switched to the load meter signal by
parameter setting.)
PA1 Disuse
SM Disuse PB1 Disuse
CH1
Analog output for internal data
observation
(Phase U current: IU)
PS1 Disuse
CH2
Analog output for internal data
observation
(Estimated motor speed : 1638 min
-1
/V)
PA2 Disuse
CH1D Output for internal data bit observation PB2 Disuse
CH2D Output for internal data bit observation PS2 Disuse
VRM Disuse PA3 Disuse
LSA1 Disuse PB3 Disuse
EXTSC1 Disuse PA4 Disuse
LSA2 Disuse PB4 Disuse
EXTSC2 Disuse OVR2 Analog override command
PAD Disuse 15V Disuse
PBD Disuse 5V +5 VDC power check
PSD Disuse -15V Disuse
GND 0 V