B-65285EN/03 START-UP PROCEDURE 4.CONFIRMATION OF THE OPERATION
- 33 -
4.3.2.3 The motor does not turn.
(1) When "--" is indicated on the STATUS display of the SPM
Check whether spindle control signals are input. (An example for
the first spindle is shown below.)
FS15i FS16i
#7 #6 #5 #4 #3 #2 #1 #0
G227 G070 MRDYA SFRA SRVA
G226 G071 *ESPA
- G029 *SSTP
- G030 SOV7 SOV6 SOV5 SOV4 SOV3 SOV2 SOV1 SOV0
(2) When "00" is indicated on the STATUS display of the SPM
No spindle speed command is input.
Refer to Chapter 1 in "FANUC AC SPINDLE MOTOR αi series
Parameter Manual (B-65280EN)," and check related parameters.
(3) When an alarm number is indicated on the SPM
See the description of the alarm number in Part II.
4.3.2.4 A specified speed cannot be obtained.
(1) When the speed always differs from a specified speed
Check parameters.
Refer to Chapter 1 in "FANUC AC SPINDLE MOTOR αi series
Parameter Manual (B-65280EN)," and check related parameters.
(2) When an alarm number is indicated on the SPM