B-65285EN/03 START-UP PROCEDURE 4.CONFIRMATION OF THE OPERATION
- 59 -
4.3.8.4 About the spindle control and spindle status signals
As stated in the previous item, the SERVO GUIDE can be used to
observe the PMC signals (spindle control signals 1 and 2 and spindle
status signals 1 and 2) used by the spindle.
Listed below is the data configuration for spindle control signals 1 and
2 and spindle status signals 1 and 2. Refer to Chapter 3, "PMC Signals
(CNC ↔ PMC)" of "FANUC AC SPINDLE MOTOR αi series
PARAMETER MANUAL" (B-65280EN) for explanations about each
signal.
(a) Spindle control signal 1 (SPCT1)
#15 #14 #13 #12 #11 #10 #9 #8
RCH RSL INTG SOCN MCFN SPSL *ESP ARST
#7 #6 #5 #4 #3 #2 #1 #0
MRDY ORCM SFR SRV CTH1 CTH2 TLMH TLML
(b) Spindle control signal 2 (SPCT2)
#15 #14 #13 #12 #11 #10 #9 #8
DSCN SORSL MPOF
#7 #6 #5 #4 #3 #2 #1 #0
RCHHG MFNHG INCMD OVR NRRO ROTA INDX
(c) Spindle status signal 1 (SPST1)
#15 #14 #13 #12 #11 #10 #9 #8
RCFN RCHP CFIN CHP
#7 #6 #5 #4 #3 #2 #1 #0
ORAR TLM LDT2 LDT1 SAR SDT SST ALM
(d) Spindle status signal 2 (SPST2)
#15 #14 #13 #12 #11 #10 #9 #8
#7 #6 #5 #4 #3 #2 #1 #0
EXOF SOREN INCST PC1DT