B-65285EN/03 TROUBLESHOOTING 3.TROUBLESHOOTING AND ACTION
- 95 -
3.2.7 Alarm Code 8
(1) Meaning
Inverter: DC link current alarm
(2) Cause and troubleshooting
(a) Disconnect the motor power leads from the SVM, and
release the SVM from an emergency stop condition.
<1> If no abnormal DC link current alarm condition has
occurred
→ Go to (b).
<2> If an abnormal DC link current alarm condition has
occurred
→ Replace the SVM.
(b) Disconnect the motor power leads from the SVM, and check
the insulation between PE and the motor power lead U, V, or
W.
<1> If the insulation is deteriorated
→ Go to (c).
<2> If the insulation is normal
→ Replace the SVM.
(c) Disconnect the motor from its power leads, and check
whether the insulation of the motor or power leads is
deteriorated.
<1> If the insulation of the motor is deteriorated
→ Replace the motor.
<2> If the insulation of any power lead is deteriorated
→ Replace the power lead.