B-65285EN/03 TROUBLESHOOTING 3.TROUBLESHOOTING AND ACTION
- 89 -
3.1.8 Alarm Code 8 (PSMR)
(1) Meaning
There is excessive short-term regenerative power.
(2) Cause and troubleshooting
(a) Insufficient regenerative resistance
→ Review the specification of the regenerative resistance.
(b) Regenerative circuit failure
→ The regenerative circuit is abnormal. Replace the
PSMR.
3.1.9 Alarm Code A (PSM)
(1) Meaning
A cooling fan of external cooling fin has stopped.
(2) Cause and troubleshooting
(a) Cooling fan of external cooling fin broken
Check whether the cooling fan of external cooling fin rotates
normally.
→ Replace it.
(b) Poor installation of the control printed-circuit board
→ Be sure to install the control printed-circuit board.
(This alarm may be issued if one of the connectors for
connection between the control printed-circuit board
and power printed-circuit board become loose.)
3.1.10 Alarm Code E (PSM, PSMR)
(1) Meaning
The input power supply is abnormal (open phase).
(2) Cause and troubleshooting
(a) The input power supply has an open phase.
Check the power supply voltage.
→ If there is no problem with the power supply voltage,
check the connections.