B-65285EN/03 TROUBLESHOOTING 3.TROUBLESHOOTING AND ACTION
- 99 -
3.2.12 Alarm Code U
(1) Meaning
Inverter: FSSB communication error (COP10B) (NOTE)
(2) Cause and troubleshooting
(a) Replace the SVM optical cable (COP10B) that is nearest to
the CNC on which "U" is displayed (in Fig. 3.2.12, the cable
between UNIT2 and UNIT3).
(b) Replace the SVM that is nearest to the CNC on which "U" is
displayed (in Fig. 3.2.12, UNIT3).
(c) Replace the COP10B-side SVM that is nearest to the CNC
on which "U" is displayed (in Fig. 3.2.12, UNIT2).
(d) Replace the servo card in the CNC.
LL U
COP10B
COP10A
COP10B
COP10A
COP10B
COP10A
Master side
(CNC side)
U
COP10B
COP10A
Slave side
UNIT1 UNIT2 UNIT3 UNIT4
Fig. 3.2.12
NOTE
When the CNC power is turned on, "U" blinks
momentarily, and then "-" steadily lights. This is not
a failure, though.