B-65285EN/03 TROUBLESHOOTING 3.TROUBLESHOOTING AND ACTION
- 91 -
3.2 SERVO AMPLIFIER MODULE
The following table lists alarms related to the servo amplifier.
See this table while comparing the CNC alarm codes presented in
Chapter 2, "Alarm Numbers and Brief Description" with the LED
displays of the SVM.
Alarm
LED
display
Major cause Reference
Inverter: internal cooling fan stopped 1
- Fan not running.
- Fan motor connector or cable defective
- SVM failure
3.2.1
Inverter: control power supply
undervoltage
2
- The 24 V control power supply output from the PSM is
low.
- Connector/cable (CXA2A/B) defective
- SVM failure
3.2.2
Inverter: DC link undervoltage 5
- Low input voltage
- DC link short-bar poor connection
- SVM failure
3.2.3
Inverter: overheat 6
- The motor is being used under a harsh condition.
- The ambient temperature is high.
- SVM failure
3.2.4
Inverter: cooling fan stopped of the
radiator
F
- Fan not running.
- Fan motor connector or cable defective
- SVM failure
3.2.5
Communication error between amplifier
and module
P
- Connector/cable (CXA2A/B) defective
- SVM failure
3.2.6
Inverter: DC link current alarm (L axis) 8
- Short-circuit between power lead phases or ground fault
in them
- Short-circuit between motor winding phases or ground
fault in them
- SVM failure
3.2.7
Inverter: IPM alarm (L axis) 8.
Inverter: IPM alarm (M axis) 9.
Inverter: IPM alarm (N axis) A.
- Short-circuit between power lead phases or ground fault
in them
- Short-circuit between motor winding phases or ground
fault in them
- SVM failure
3.2.8
Inverter: IPM alarm (OH) (L axis) 8.
Inverter: IPM alarm (OH) (M axis) 9.
Inverter: IPM alarm (OH) (N axis) A.
- The motor is being used under a harsh condition.
- The ambient temperature is high.
- SVM failure
3.2.9
Inverter: DC link current alarm (L axis) b
Inverter: DC link current alarm (M axis) c
Inverter: DC link current alarm (N axis) d
- Short-circuit between power lead phases or ground fault
in them
- Short-circuit between motor winding phases or ground
fault in them
- Incorrect motor ID setting
- SVM failure
- Motor failure
3.2.10
Inverter: abnormal control power supply
Blinking
-
- Connector or cable (JF*) failure
- Motor failure
- SVM failure
3.2.11
Inverter: FSSB communication error
(COP10B)
U
- Connector or cable (COP10B) failure
- SVM failure
- CNC failure
3.2.12