B-65285EN/03 TROUBLESHOOTING 3.TROUBLESHOOTING AND ACTION
- 123 -
3.4.18 Alarm Code 36
The error counter overflowed.
(1) The setting of a parameter is incorrect.
(a) The gear ratio set in a parameter is incorrect.
Check if an excessively large gear ratio is set.
(b) The setting of a position gain is incorrect.
If the gear ratio data is correct, increase the position gain.
FS15i FS16i
Description
3056 to 3059 4056 to 4059 Gear ratio between the spindle and motor
3060 to 3063 4060 to 4063 Position gain at orientation
3065 to 3068 4065 to 4068
Position gain in the servo mode/spindle
synchronization
3069 to 3072 4069 to 4072 Position gain in Cs contour control
(2) Sequence error
(a) Check if the motor is deactivated (by turning off SFR/SRV)
in a position control mode (rigid tapping, Cs contour control,
or spindle synchronization).
3.4.19 Alarm Code 37
After emergency stop signal input, the motor is accelerated without
being decelerated. This alarm is issued also when the motor is not
deactivated (the motor is not decelerated completely) when the
acceleration/deceleration time (initial parameter setting: 10 seconds)
has elapsed after emergency stop signal input.
Troubleshooting when this alarm is issued
(a) The parameter setting of the speed detector is incorrect.
Referring to Chapter 1 in "FANUC AC SPINDLE MOTOR αi
series Parameter Manual (B-65280EN)," set a correct time.
(b) The parameter setting of an acceleration/deceleration time is not
proper.
Check the parameter-set value and actual acceleration/
deceleration time, then set an actual acceleration/deceleration
time plus some margin.
FS15i FS16i
Description
3082 4082 Acceleration/deceleration time setting