OPERATION
B–63834EN/02
7. ALARM AND SELF–DIAGNOSIS
FUNCTIONS
459
When an alarm occurs, the alarm screen appears.
ARALM
ALARM MESSAGE
MDI
* * * *
* * * * * *
18 : 52 : 05
0000
00000
100 PARAMETER WRITE ENABLE
510 OVER TRAVEL :+X
417 SERVO ALARM : X AXIS DGTL PARAM
MSG
HISTRY
ALM
417 SERVO ALARM : Z AXIS DGTL PARAM
In some cases, the alarm screen does not appear, but an ALM is displayed
at the bottom of the screen.
INPUT+INPUTOFF:0ON:1NO.SRH
ALM
PARAMETER (AXIS/UNIT) O1000 N00010
MEM
* * * *
* * * * * *
08 : 41 : 27
S 0 T0000
1001 INM
00000000
1002 NFD XIK DLZ JAX
00000000
1003
00000000
1004 IPR ISC
00000000
>_
In this case, display the alarm screen as follows:
1 Press the function key
MESSAGE
.
2 Press the chapter selection soft key
[ALARM].
7.1
ALARM DISPLAY
Explanations
D Alarm screen
D Another method for
alarm displays