OPERATION
B–63834EN/02
11. SETTING AND DISPLAYING DATA
615
The current mode, automatic operation state, alarm state, and program
editing state are displayed on the next to last line on the CRT screen
allowing the operator to readily understand the operation condition of the
system.
If data setting or the input/output operation is incorrect, the CNC does not
accept the operation and a warning message is displayed on the next to last
line of the CRT screen. This prevents invalid data setting and input/output
errors.
EDIT STOP MTN FIN ALM hh:mm:ss INPUT
––EMG––
(8)
(1)
(2) (3) (4)
(5)
(6) (7)
(Display soft keys)
(9) Data is out of range.
(Note) Actually, this is displayed in the area starting
from (2).
(Note) Actually, 5 is displayed
in the area for (3) and (4).
Note) Actually, (10) is displayed at the position where (8) is now
displayed.
MDI : Manual data input, MDI operation
MEM : Automatic operation (Memory operation)
RMT : Automatic operation (DNC operation)
EDIT : Memory editing
HND : Manual handle feed
JOG : Jog feed
TJOG : TEACH IN JOG
THND : TEACH IN HANDLE
INC : Manual incremental feed
REF : Manual reference position return
**** : Reset (When the power is turned on or the state in which
program execution has terminated and automatic operation has
terminated.
STOP : Automatic operation stop (The state in which one block has
been executed and automatic operation is stopped.)
HOLD : Feed hold (The state in which execution of one block has been
interrupted and automatic operation is stopped.)
STRT : Automatic operation start–up (The state in which the system
operates automatically)
MTN : Indicates that the axis is moving.
DWL : Indicates the dwell state.
*** : Indicates a state other than the above.
FIN : Indicates the state in which an auxiliary function is being
executed. (Waiting for the complete signal from the PMC)
*** : Indicates a state other than the above.
––EMG––
: Indicates emergency stop.(Blinks in reversed display.)
––RESET–– : Indicates that the reset signal is being received.
11.6.2
Displaying the Status
and Warning for Data
Setting or Input/Output
Operation
Explanations
D Description of each
display
D (1) Current mode
D (2) Automatic operation
status
D (3) Axis moving
status/dwell status
D (4) State in which an
auxiliary function is
being executed
D (5) Emergency stop or
reset status