OPERATION11. SETTING AND DISPLAYING DATA
B–63834EN/02
564
The reading on the load meter can be displayed for each servo axis and
the serial spindle by setting bit 5 (OPM) of parameter 3111 to 1. The
reading on the speedometer can also be displayed for the serial spindle.
Procedure for displaying the operating monitor
1 Press function key
POS
to display a current position display screen.
2 Press the continuous–menu key
.
3 Press soft key
[MONI].
X : * * * 80% S1 : 201%
Z : * * * * * 0% (SPEED METER RPM)
C : * * * * * 0% S1 : * * *
1500
OPERATING MONITOR O0001 N00001
(LOAD METER)
[
MEM STRT MTN *** 09:06:35
[ MONI ][ REL ][ ALL ][ HNDL ][ OPRT ]
PART COUNT 5
RUN TIME 0H15M CYCLE TIME 0H 0M38S
ACT.F 3000 MM/M
The reading on the load meter can be displayed for up to three servo axes
by setting parameters 3151 to 3158.
When all these parameters are set to 0, data is displayed only for the basic
axes.
When serial spindles are used, the reading on the load meter and
speedometer can be displayed only for the main serial spindle.
The bar graph for the load meter shows load up to 200% (only a value is
displayed for load exceeding 200%). The bar graph for the speedometer
shows the ratio of the current spindle speed to the maximum spindle speed
(100%).
11.1.7
Operating Monitor
Display
Explanations
D Display of the servo axes
D Display of the spindle
axes
D Unit of graph