OPERATION11. SETTING AND DISPLAYING DATA
B–63834EN/02
606
Tool life data can be displayed to inform the operator of the current state
of tool life management. Groups which require tool changes are also
displayed. The tool life counter for each group can be preset to an
arbitrary value. Tool data (execution data) can be reset or cleared. To
register or modify tool life management data, a program must be created
and executed. See Explanations in this section for details.
Procedure for display and setting the tool life management data
1 Press function key
OFFSET
SETTING
.
2 Press the continuous menu key to display chapter selection soft
key
[TOOLLF].
3 Press soft key
[TOOLLF].
4 One page displays data on two groups. Pressing page key
PAGE
or
PAGE
successively displays data on the following groups. Up to four
group Nos., for which the Tool Change signal is being issued, are
displayed at the bottom of each page. An arrow shown in the figure is
displayed for five or more groups, if exists.
TOOL LIFE DATA : O3000 N00060
SELECTED GROUP 000
GROUP 001 : LIFE 0150 COUNT 0000
0034 0078 0012 0056
0090 0035 0026 0061
0000 0000 0000 0000
0000 0000 0000 0000
GROUP 002 : LIFE 1400 COUNT 0000
0062 0024 0044 0074
0000 0000 0000 0000
0000 0000 0000 0000
0000 0000 0000 0000
TO BE CHANGED : 003 004 005 006 –––>
> _
MEM **** *** *** 16:05:59
[ MACRO ][ ][ OPR ][ TOOLLF ][ (OPRT) ]
5 To display the page containing the data for a group, enter the group
number and press soft key
[NO.SRH].
The cursor can be moved to an arbitrary group by pressing cursor key
or .
6 To change the value in the life counter for a group, move the cursor to
the group, enter a new value (four digits), and press
[INPUT]. The life
counter for the group indicated by the cursor is preset to the entered
value. Other data for the group is not changed.
11.4.14
Displaying and Setting
Tool Life Management
Data
TOOLLF
Continuous menu key