PROGRAMMING11. AUXILIARY FUNCTION
B–63004EN/02
132
Indexing of the table is performed by address B and a following 8–digit
number. The relationship between B codes and the corresponding
indexing differs between machine tool builders.
Refer to the manual issued by the machine tool builder for details.
0 to 99999999
1. The decimal point can be used for input.
Command Output value
B10. 10000
B10 10
2. It is possible to change over the scale factor of B output, 1000 or 1
when the decimal point input is omitted, using the parameter DPI (No.
3401#0).
Command Output value
When DPI is 1: B1 1000
When DPI is 0: B1 1
3. It is possible to change over the scale factor of B output 1000 or 10000
when the decimal point input is omitted in the inch input system, using
the parameter AUX (No. 3405#0) When DPI=1.
Command Output value
When AUX is 1: B1 10000
When AUX is 0: B1 1000
When this functions is used, the B address specifying an axis movement
disabled.
11.4
THE SECOND
AUXILIARY
FUNCTIONS
(B CODES)
Explanations
D Command range
D Command method
Restrictions