APPENDIXG. ALARM LIST
B–63004EN/02
830
Number ContentsMessage
5251 ILLEGAL PARAMETER IN G54.2 A fixture offset parameter (No. 7580 to 7588) is illegal. Correct the pa-
rameter.
5252 ILLEGAL P COMMAND IN G54.2 The P value specifying the offset number of a fixture offset is too large.
Correct the program.
5257 G41/G42 NOT ALLOWED IN MDI
MODE
G41/G42 (cutter compensation C: M series, tool–nose radius com-
pensation: T series) was specified in MDI mode. (Depending on the set-
ting of bit 4 of parameter No. 5008)
5303 TOUCH PANEL ERROR A touch panel error occurred.
Cause:
1. The touch panel is kept pressed.
2. The touch panel was pressed when power was turned on.
Remove the above causes, and turn on the power again.
2) Background edit alarm
Number Message Contents
070 to 074
085 to 087
BP/S alarm BP/S alarm occurs in the same number as the P/S alarm that occurs
in ordinary program edit.
140 BP/S alarm It was attempted to select or delete in the background a program be-
ing selected in the foreground. (NOTE)
Use background editing correctly.
NOTE
Alarm in background edit is displayed in the key input line of the background edit screen instead
of the ordinary alarm screen and is resettable by any of the MDI key operation.
3) Absolute pulse coder (APC) alarm
Number Message Contents
300 n AXIS NEED ZRN Manual reference position return is required for the nth–axis (n=1 to 8).
301 APC ALARM:n AXIS
COMMUNICATION
nth–axis (n=1 to 8) APC communication error. Failure in data transmission
Possible causes include a faulty APC, cable, or servo interface module.
302 APC ALARM:n AXIS
OVER TIME
nth–axis (n=1 to 8) APC overtime error.
Failure in data transmission.
Possible causes include a faulty APC, cable, or servo interface module.
303 APC ALARM:n AXIS
FRAMING
nth–axis (n=1 to 8) APC framing error. Failure in data transmission.
Possible causes include a faulty APC, cable, or servo interface module.
304 APC ALARM:n AXIS
PARITY
nth–axis (n=1 to 8) APC parity error.
Failure in data transmission. Possible causes include a faulty APC, cable, or
servo interface module.
305 APC ALARM:n AXIS
PULSE MISS
nth–axis (n=1 to 8) APC pulse error alarm.
APC alarm. APC or cable may be faulty.
306 APC ALARM:n AXIS
BATTERY ZERO
nth–axis (n=1 to 8) APC battery voltage has decreased to a low level so that the
data cannot be held.
APC alarm. Battery or cable may be faulty.
307 APC ALARM:n AXIS
BATTERY DOWN 1
nth–axis (n=1 to 8) axis APC battery voltage reaches a level where the battery
must be renewed.
APC alarm. Replace the battery.