PROGRAMMING
B–63004EN/02
20. TWO–PATH CONTROL
FUNCTION
385
Display and set tool shape data (interference forbidden areas) according
to the procedure below.
(1)Press function
OFFSET
SETTING
key.
(2)Press the chapter selection soft key
[TOOLFM].
(3)With the tool post selection signal, select a tool post for which
interference forbidden areas for tool post interference checking are to
be displayed and set.
(4)Display the screen including a tool number for which data is to be set.
Method 1:Select the screen by using the page keys and cursor keys.
Method 2:Enter a desired tool number, then press the soft key
[NO.SRH]
TOOL FORM DATA
O0001 N00001
OFFSET NO. = 01
AREA1
X = 20.000
Z = 70.000
I = –10.000
K = –50.000
OFFSET NO = 02
AREA1
X= 80.000
Z = 170.000
I = –100.000
K = –120.000
AREA 2
X = 40.000
Z = 70.000
I = 20.000
K = 30.000
AREA 2
X = –100.000
Z = –60.000
I = –140.000
K = –120.000
MEM
* * * *
* * * * * *
12 : 02 : 08 HEAD1
_
S 0 T0000
[ NO.SRH ][ ][ ][ +INPUT ][ INPUT ]
(5)Move the cursor to a data item to be set, with the cursor move keys.
(When data for point A is to be set, move the cursor to X and Z.
When data for point B is to be set, move the cursor to I and K.)
(6)With the numeric keys, enter the coordinates of point A or B.
(Fraction digits can be entered.)
X
Z
A (X, Z)
B (I, K)
X > I
Z > K
(7)By pressing the soft key [INPUT], the entered coordinates are set.
(Press the soft key
[+INPUT] when an entered numeric value is to set
after it is added to data already set.)
20.3.3
Setting and Display of
Interference Forbidden
Areas for Tool Post
Interference Checking
Explanations