B–64115EN/01
1. DISPLAY AND OPERATION
133
The data file of parameters saved in CNC memory or a memory card as
a program is written into the slave determined by the program number.
The program number and memory device are determined as described in
“Saving parameters.”
1. Select the active slave.
2. Press the [(OPRT)] soft key. The following soft keys appear:
[ NO.SRC ][ ][ ][ ][ INPUT ]
3. Press the next–menu key. The following soft keys appear:
[ ][ READ ][ PUNCH ][ ][ ]
4. Press the [PUNCH] soft key. The following soft keys appear:
[ ][ ][ ][CANCEL ][ EXEC ]
5. Press the [EXEC] soft key.
During output, “INPUT” blinks in the message field.
The screen cannot be changed to another screen during parameter
input/output.
When the RESET key is pressed, or when an alarm status is detected in
communication, the input/output stops.
D Writing parameters