4. INTERFACE BETWEEN CNC AND PMC
B–64115EN/01
264
Series 0i–C/0i Mate–C Series 0i–C
PMC–SA1 PMC–SB7
Programming method Ladder Ladder
Number of ladder levels 2 3
1st level execution period 8ms 8ms
Basic instruction execution time 5.0m sec/step 0.0033m sec/step
Program size
D Ladder
D Symbol/comment
D Message
5,000 steps max.
1 to 128 KB
0.1 to 64 KB
Approx. 24,000 steps max.(NOTES 1,
2)
1 KB and up (NOTE 2)
8 KB and up (NOTE 2)
Instruction (basic)
(functional)
12
48
14
69
Intemal relay (R)
Extended relay (E)
Message request (A)
Nonvolatile memory and so on
D Data table (D)
D Variable timer (T)
Fixed timer
D Counter (C)
Fixed counter (C)
D Keep relay (K)
Subprogram (P)
Label (L)
1,100 bytes
–
200 requests (25 bytes)
1,860 bytes
40 units (80 bytes)
100 units
20 units (80 bytes)
–
20 bytes
–
–
8,500 bytes
8,000 bytes
2,000 requests (500 bytes, 2 bits/request)
10,000 bytes
250 units (1,000 bytes, 4 bytes/unit)
500 units (timer number specification)
100 units (400 bytes, 4 bytes/unit)
100 units (200 bytes, 2 bytes/unit)
120 bytes
2,000 programs
9,999 units
Input/output (I/O Link)
D Input
D Output
240 points max.
160 points max.
1,024 points max.
1,024 points max.
Sequence program storage memory Flash ROM
128KB
Flash ROM
128 KB
256 KB
NOTE
1 The maximum number of steps assumes programming using basic instructions. The maximum
number of steps varies according to the status of functional instruction use.
2 The total sequence program size (including all of the ladders, symbols/comments, and
messages) must not exceed the capacity of the sequence program storage memory. If the size
of any of the ladders, symbols/comments, or messages is greater, the maximum allowable size
of the others may be limited.
4.2
SPECIFICATION OF
PMC
4.2.1
Specification