B–64115EN/01
7. AC SPINDLE (SERIAL INTERFACE)
407
Select a spindle for which data is to be set.
S11: Main spindle amplifier for the 1st spindle
S12: Subspindle amplifier for the 1st spindle
S21: Main spindle amplifier for the 2nd spindle
S22: Subspindle amplifier for the 2nd spindle
4216 4216
4217 4217
S11:1st Main
S12:1st Sub
S21:2nd Main
S22:2nd Sub
Gear ratio(HIGH) 4056 4056
Gear ratio(MIDIUM HIGH) 4057 4057
Gear ratio(MIDIUM LOW) 4058 4058
Gear ratio(LOW) 4059 4059
Max. spindle speed
(gear1)
3741
3742 3742
3743 3743
3744 3744
Max. motor speed 4020 4196 4020 4196
Max. C axis speed 4021 None 4021 None
3741
Max. spindle speed
(gear2)
Max. spindle speed
(gear3)
Max. spindle speed
(gear4)
OPERATION : SPEED CONTROL
GEAR SELECT : 1
SPINDLE : S11
(MONITOR)
MOTOR SPEED 100
SPINDLE SPEED 150
POS ERR S1 100
POS ERR S2 103
SYN.ERR 3
SPINDLE TUNING
(PARAMETER)
PROP.GAIN 20
INT.GAIN 50
LOOP GAIN 3000
MOTOR VOLT 30
TIME CONST 100
REF. SHIFT 2046
1 : Normal operation
2 : Orientation
3 : Synchronization control
4 : Rigid tapping
5 : Cs contour control
6 : Spindle positioning control
D Spindle
D Parameters
7.1.2.3
Spindle tuning screen
D Operation mode