B–64115EN/01
7. AC SPINDLE (SERIAL INTERFACE)
411
S11:
1st Main
S12:
1st Sub
S21:
2nd Main
S22:
2nd Sub
Proportional gain(HIGH) 4040 4206 4040 4206
Proportional gain (LOW) 4041 4207 4041 4207
Integral gain(HIGH) 4048
4048
Integral gain(LOW) 4049
4049
Motor voltage 4083 4236 4083 4236
Regenerative power 4080 4231 4080 4231
S11:
1st Main
S12:
1st Sub
S21:
2nd Main
S22:
2nd Sub
Proportional gain(HIGH) 4042 4208 4042 4208
Proportional gain (LOW) 4043 4209 4043 4209
Integral gain(HIGH) 4050
4050
Integral gain(LOW) 4051
4051
Loop gain (HIGH) 4060
4060
Loop gain (MID, HIGH) 4061
4061
Loop gain (MID, LOW) 4062
4062
Loop gain (LOW) 4063
4063
Motor voltage 4084 4237 4084 4237
Gain change upon completion
of orientation
4064 4220 4064 4220
Stop position shift 4077 4228 4077 4228
PC–type orientation stop posi-
tion
4031 4204 4031 4204
7.1.2.5
Correspondence
between operation mode
and parameters on
spindle tuning screen
D Normal operation mode
D Orientation mode