7. AC SPINDLE (SERIAL INTERFACE)
B–64115EN/01
406
(1)Confirm the parameters
#7
3111
#6 #5 #4 #3 #2 #1
SPS
#0
Bit1 (SPS) 0 : The spindle tuning screen is not displayed.
l 1 : The spindle tuning screen is displayed.
(2)Press the
SYSTEM
key to select the screen for setting parameters and other
data.
(3)Press the continuous menu key
.
(4)Press the soft key [SP.PRM]. Then, the spindle setting and tuning
screen appears.
(5)The following screens are provided. These screens can be selected
using soft keys.
1) [SP.SET] : Spindle setting screen
2) [SP.TUN] : Spindle tuning screen
3) [SP.MON] : Spindle monitor screen
(6)With the page keys
PAGE
PAGE
, a spindle to be displayed can be
selected (only when multiple serial spindles are connected).
SPINDLE SETTING
(1)GEAR SELECT : 1
(2)SPINDLE : S11
(PARAMETER)
(3)GEAR RATIO 50
(4)MAX SPINDLE SPEED 3000
(5)MAX MOTOR SPEED 6000
(6)MAX C AXIS SPEED 100
The gear select status on the machine side is displayed.
Indication CTH1 CTH2
1
2
3
4
0
0
1
1
0
1
0
1
7.1.2
Spindle Setting and
Tuning Screen
7.1.2.1
Display method
7.1.2.2
Spindle setting screen
D Gear selection