B–64115EN/01
E. FSSB START–UP PROCEDURE/
MATERIALS
APPENDIX
643
The FSSB setting screen displays FSSB–based amplifier and axis
information, and allows amplifier and axis information to be set.
1 Press function key
SYSTEM
.
2 Pressing the continuous menu key
several times displays
[FSSB].
3 Pressing soft key [FSSB] switches the screen display to the amplifier
setting screen (or the FSSB setting screen selected previously), and
displays the following soft keys:
[ AMP ][ AXIS ][ MAINT ][ ][ (OPRT) ]
There are three types of FSSB setting screens: the amplifier setting screen,
axis setting screen, and amplifier maintenance screen.
Pressing soft key [AMP] switches the screen display to the amplifier
setting screen.
Pressing soft key [AXIS] switches the screen display to the axis setting
screen.Pressing soft key [MAINT] switches the screen display to the
amplifier maintenance screen.
The amplifier setting screen displays slave information divided into
amplifier information and separate detector interface unit information.
(AMPLIFIER SETTING) O1000 N00001
NO.
1 A1–L α SVM–HV 40AL 1 X
2 A1–M α SVM 12A 2 Y
3 A2–L β SVM 40A 3 Z
4 A3–L α SVM 20A 4 A
5 A3–M α SVM 40A 5 B
7 A4–L α SVU 240A 6 C
NO. PCB ID
6 M1 A 0000 DETECTOR(8AXES)
8 M2 B 12AB
>_
MDI **** *** *** 13:11:56
[ AMP ][ AXIS ][ MAINT ][ ][ (OPRT) ]
The amplifier setting screen displays the items below.
D NO.: Slave number
The serial numbers for to up to ten slaves (up to eight amplifiers and
up to two pulse modules) connected via the FSSB are displayed
sequentially. A younger number is assigned to a slave closer to the
CNC.
D AMP: Amplifier type
Amplifier type information starts with the character A, which stands
for “amplifier.” The character A is followed by the ordinal number of
an amplifier counted from the amplifier closest to the CNC, then is
followed by a letter indicating which axis of the amplifier is used (L
for the first axis, and M for the second axis).
E.8
FSSB DATA DISPLAY
E.8.1
Amplifier Setting
Screen