1. DISPLAY AND OPERATION
B–64115EN/01
74
362 Cumulative command pulse count (SV)
DGN
[Data type] Two–word axis
[Unit of data] Detection unit
[Valid data range] –99999999 to 99999999
Indicates the cumulative count of movement command and compensation
pulses received at the servo section since the power was switched on.
363 Cumulative feedback pulse count (SV)
DGN
[Data type] Two–word axis
[Unit of data] Detection unit
[Valid data range] –99999999 to 99999999
Indicates the cumulative count of position feedback pulses received from
the pulse coder by the servo section.
380 Difference between the absolute position of the motor and offset data
DGN
[Data type] Two–word axis
[Units of data] Detection units
M (absolute position of the motor) – S (offset data)
λ(pitch interval)
The remainder resulting from the division is displayed.
381 Offset data from the Inductosyn
DGN
[Data type] Two–word axis
[Units of data] Detection units
Off set data is displayed when CNC calculates the machine position.
D Diagnostic data related
to the Inductosyn
absolute position
detector