7. AC SPINDLE (SERIAL INTERFACE)
B–64115EN/01
414
The standard parameters related to each motor model can be set
automatically.
D The specifications for controlling a motor depend on the specifications
defined by the machine tool builder. The parameters defined by the
machine tool builder are set as the standard values (initial values) by
this automatic setting function.
Therefore, when performing automatic operation, always set
parameters properly according to the parameter list (parameters
4000 and later).
1. Turn on the power in the emergency stop state.
2. Set bit 7 of parameter 4019 to 1.
#7
LDSP4019
#6 #5 #4 #3 #2 #1 #0
Bit 7 (LDSP) The parameters for the serial interface spindle are:
0 : Not set automatically.
l 1 : Set automatically.
3. Set a motor model code.
4133 Motor model code
(Reference: Example of motor model code)
Code Motor model Amplifier
308 a 3/10000i (1500/10000min
–1
) SPM–5.5i
312 a 8/8000i (1500/8000min
–1
) SPM–11i
401 a 6/12000i (1500/12000min
–1
, 4000/12000min
–1
) SPM–11i
314 a 12/7000i (1500/7000min
–1
) SPM–15i
316 a 15/7000i (1500/7000min
–1
) SPM–22i
320 a 22/7000i (1500/7000min
–1
) SPM–26i
406 a 22/10000i (1500/10000min
–1
, 4000/10000min
–1
) SPM–26i
322 a 30/6000i (1150/6000min
–1
) SPM–45i
323 a 40/6000i (1500/6000min
–1
) SPM–45i
411 a P30/6000i (400/1500min
–1
, 575/6000min
–1
) SPM–22i
413 a P50/6000i (575/1500min
–1
, 1200/6000min
–1
) SPM–26i
242 a C3/6000i (1500/6000min
–1
) SPMC–5.5i
243 a C6/6000i (1500/6000min
–1
) SPMC–11i
244 a C8/6000i (1500/6000min
–1
) SPMC–11i
245 a C12/6000i (1500/6000min
–1
) SPMC–15i
246 a C15/6000i (1500/6000min
–1
) SPMC–22i
For motor model codes other than the above, refer to the parameter
manual for spindles.
The α Series cannot be used with the 0i Mate.
4. Turn off the power then back on. Then, the parameters are read.
7.1.3
Automatic Setting of
Standard Parameters