Title 90A3 / 90A7 / 90B3 / 90B7
Learning Control Operator’s Manual
03 ’05.01.13 K.Maeda 3
rd
. updated. Draw No.
02 '03.01.06 K.Maeda 2
nd
. updated
A - 63639E - 070
01 ‘00.09.20 K.Maeda Newly designed Sheet 018
Edit Date Design Description
/ 081
5.3 Servo HRV3 setting
As Learning series bases on standard series, refer to "FANUC AC SERVO MOTOR αi series Parameter
Manual" (B-6570E). HRV3 is available for Learning series of 90B3 and 90B7.
The following describes the special points in Learning series.
(Note) From 90B3/08(H) or later and 90B7/08(H) or later, High speed HRV control (HRV3) and is Velocity
gain magnification (No.2335) is available.
5.3.1 Case of ITP 250µs in Piston Lathe or Lead cutting machine
Piston axis or Turner axis is set parameters referring to Appendix 3. Parameter table for Learning control.
You should check the parameters; No.2003#0 = 1, No.2004 = xx1x1010
This setting is different from standard HRV3 setting, which does not require the NC program "G05.4 Q1".
This setting is fixed in the high-speed current control mode. Servo amplifier requires "
αSVM1-80"
(A06B-6096-H105#H). FSSB connection is referred to the following (2) Case of two FSSB paths
.
5.3.2 HRV3 setting for high current gain with cam grinding machine
High gain setting is modified as follows. This setting is fixed in the high-speed current mode (62.5µsec
current sample) .
No.2003#0=1, No.2004=00101000, No.2040=(HRV1 setting)×0.6, No.2041=(HRV1 setting)×2.4
No.2060=5097 (70% of standard setting), No.2013#0=0