Title 90A3 / 90A7 / 90B3 / 90B7
Learning Control Operator’s Manual
03 ’05.01.13 K.Maeda 3
rd
. updated Draw No.
02 '03.01.06 K.Maeda 2
nd
. updated
A - 63639E - 070
01 ‘00.09.20 K.Maeda Newly designed Sheet 079
Edit Date Design Description / 081
1-7. Changing the sampled time
By the following operating, you can change the sampled time. When you change the sampled time, the
data file name (xxxxxxxx.BIN or xxxxxxxx.BMP) is changed.
Shift-key + ‘.’ increment
Shift-key + ‘,’ decrement
1-8. Displaying HELP
By the following operating, on-line HELP displays.
Shift-key + ‘/’
1-9. I/O wait setting
In case that you gather the data of plural axes at the same time, if you can not gather the 2
nd
axis data,
you should increase the I/O wait from 1 (default) to 5 in SYSTEM setting screen of SD.EXE.
7.5 Notes
The parameters setting example (only Learning series)
* 1
st
. arbitrary data serial output (pair of No.2115 and No.2151) axis 5 on digital check board
* 2
nd
. arbitrary data serial output (pair of No.2152 and No.2153) axis 6 on digital check board
No.2115 No.2151 1
st
. arbitrary data serial output
No.2152 No.2153 2
nd
. arbitrary data serial output
Position FB (L axis) 4788 0
(detection unit) 4 555
SUMPSL
Error (L axis) 4884 0
(detection unit) 4 561
ERCNLL
Tcmd (L –axis) 8914 0
2 813
WUCMDL
Current command (L) 20530 0
2 1283
WTCMDL
Mcmd (L-axis) *1 4660 0
(detection unit) 4 *2 547
WMODAT
*1) 4660 (1234h) for 90B3/07, 90B7/07 or later. 5236 (1474h) for the other case.
*2) 4660 (1234h) for 90B3/07, 90B7/07 or later. 5236 (1474h) for the other case.