9-5. Axis allocation of 2 controlled paths in i-series
In case that you allocate Servo axis by No.1023 in 2 controlled paths in i-series, you must not allocate the
servo axes of the another controlled path to one servo DSP.
(Bad example)
[1
st
path]
X
1
axis No.1023 = 1 → L-axis of 2 axes amplifier
• • • •
[2
nd
path]
X
2
axis No.1023 = 2 → M-axis of 2 axes amplifier
• • • •
(Good example)
[1
st
path]
X
1
axis No.1023 = 1 → L-axis of 2 axes amplifier
• • • •
[2
nd
path]
X
2
axis No.1023 = 4 → M-axis of 2 axes amplifier
• • • •
9-6. Servo parameter alarm for Learning control
If you set the value out of appropriate range in parameters for learning control, the illegal parameter alarm
occurs immediately after G05 was executed, and the detail number 83 is displayed on N352 in DGN. In this
case, if the following parameters are set, furthermore detailed alarm information is displayed on N353 in
DGN. This value has to convert decimal one to binary one and check the said bit parameter.
N2115=0
N2151=1913 (779h)
The value of N353 in DGN
B3 : Filter frequency band of low pass filter (N2244) was out of range.
B4 : Profile number (N2233) was out of range.
B5 : Learning period (N2243,N2236,N2238,N2240,N2266) was out of range.
B6 : Total profile number (N2264) was out of range.
B7 : Learning memory clear hasn’t been completed yet.
B8 : When total profile number (N2264) wasn’t zero, profile number (N2233) was set to zero.
B9 : Learning period was too long.
Ref. HRV control
9083/01 and 9087/01 don’t support a part of HRV control in standard series (9080 series etc). Therefore you
must set the following parameters to 0 to avoid HC alarm in this edition after parameter loading
automatically.
You don’t need to set this in 9083/02 or later, 9087/02 or later, 90A3 and 90A7 series because those series
support all function of HRV control.
• Set No.2056 to 0. ← Case that standard parameter is negative.
• Set No.2127 to 0
.
• Set No.2128 to 0.
• Set No.2129 to 0.