Title 90A3 / 90A7 / 90B3 / 90B7
Learning Control Operator’s Manual
03 ’01.01.13 K.Maeda 3
rd
. updated Draw No.
02 '03.01.06 K.Maeda 2
nd
. updated
A - 63639E - 070
01 ’00.09.20 K.Maeda Newly designed Sheet 041
Edit Date Design Description / 081
LEBFEX Learning period is (90B7/N, 90B3/O)
1 : Available (2 words type)
0 : Not available (conventional type)
(Note) When this bit is available, Learning period is the product of the following two parameters.
But Learning step is fixed to the first step.
(Example) Case that you want to do Learning period for 64 seconds,
you should set No.2226#4 = 1, No.2243 = 10, No.2236 = 6400.
Learning period = 10 × 6400 = 64000 (msec)
(Note) Above setting enables Learning period for 32 seconds, but there is a possibility that sampling period
becomes rough by 7.1.3 Cautions, and work precision may turn worse. In that case, it is necessary to
reduce the Profile all number.
2226
LCT2WD
2243
PRIOD1 1
st
Learning period (msec)
2236
PRIOD2 2
nd
Learning period (msec)