Title 90A3 / 90A7 / 90B3 / 90B7
Learning Control Operator’s Manual
03 ’05.01.13 K.Maeda 3
rd
. updated. Draw No.
02 '03.01.06 K.Maeda 2
nd
. updated
A - 63639E - 070
01 ‘00.09.20 K.Maeda Newly designed Sheet 028
Edit Date Design Description
/ 081
VFB2MS Velocity feedback is (9087/01 or later)
1 : special. (2msec) ♦ This bit is effective to reduce high frequency
0 : standard. (1msec) oscillation in High gain setting.
VFB500 In High-speed Proportional gain, velocity feedback to P is (9083/02 or later)
1 : Average during 500µsec ♦ This bit is effective to reduce high frequency
0 : standard. (250µsec) oscillation in No.2007#0 = 1.
VFB1MS High-speed Proportional gain, velocity feedback to P is (9083/02 or later)
1 : Average during 1 msec ♦ This bit is a use of reducing high frequency
0 : standard. (250µsec) oscillation in No.2007#0 = 1.
HSSATU In High-speed Proportional gain (No.2007#0 = 1) (9087/01 or later)
1 : Wind-up of Velocity Integral is suppressed.
0 : Not suppressed (Standard at No.2007#7=0,which is usually used in No.2007#0 = 1)
TCAVE Average torque is (90Bx/03 or later)
1 : outputted (Note) You must set 1 for No.2208#7 at same time.
0 : not outputted
2228
SYSLRN
HSBLC
VFB1MSVFB500FRQ
VFB2MS
2229
ABSEN
RCNEG
TIMADJ
HSSATUSTPREDTAWAMI
2270
TIABG
DSTWAV
DSTIX
2271
HRV3AL
TCAVE