FANUC Series 16i/18i/21i-MA/MB/TB TOOL MANAGEMENT FUNCTION A-78614EN
2002.08.08 Edition 04
8
Data details
Data details of each data number are shown in the table below.
•Tool type number(T code)
Item Content
Data length 4byte
Valid data range 0,1 to 99,999,999
•Tool life counter
Item Content
Data length 4byte
Data unit count
time (second)
Valid data range count:0 to 99,999,999
time:0 to 3,599,999 (999H59M59S)
(Notice)
This value is used for the number of count (or time). Rest life value is
[Maximum of tool life value - tool life counter number].
•Maximum of tool life
Item Content
Data length 4byte
Data unit count
time (second)
Valid data range count:0 to 99,999,999
time:0 to 3,599,999 (999H59M59S)
•Previous notice life
Item Content
Data length 4byte
Data unit count
time (second)
Valid data range count:0 to 99,999,999
time:0 to 3,599,999 (999H59M59S)
When the remainder longevity value of the tool ( = maximum tool life value
- tool life counter) becomes below a set value by setting the values other
than 0, tool life previous notice signal TLCHB<F064#3> is output.