1. DISPLAY AND OPERATION OF CRT/MDI
B–62755EN/01
88
When an option which uses the SRAM area is added, the system software
may require more SRAM than is currently installed in the system. In this
case, an allocation error screen appears the first time the system is turned
on after the addition of the option, thus restoring the state existing before
the addition.
FILE ALLOCATION ERROR
S–RAM CAPACITY IS NOT SUFFICIENT.
ADDITIONAL S–RAM IS NECESSARY.
PLEASE PRESS <CAN> KEY :
RETURN TO THE STATE BEFORE
OPTION PARAMETER IS CHANGED.
*1
CAUTION (*1)
When the currently installed SRAM is not sufficient,
additional SRAM can be mounted. Newly installed SRAM
must be cleared before it can be used.
Operation:When turning on the power, hold down the
following keys:
+ for M/T series
+ for two–path control (Main)
+ for two–path control (Sub)
When installing additional SRAM, however, perform all
clear.
O
2
1
DELETE
O
O
D Allocation error screen