APPENDIX
B–62755EN/01
B. ALARM LIST
437
Number ContentsMessage
5063 IS NOT PRESET AFTER REF.
(M series)
Function category:
Workpiece thickness measurement
Alarm details
The position counter was not preset before the start of workpiece thick-
ness measurement. This alarm is issued in the following cases:
(1) An attempt has been made to start measurement without first estab-
lishing the origin.
(2) An attempt has been made to start measurement without first pre-
setting the position counter after manual return to the origin.
5064 DIFFERRENT AXIS UNIT (IS–B,
IS–C)
(M series)
Circular interpolation has been specified on a plane consisting of axes
having different increment systems.
5065 DIFFERENT AXIS UNIT (PMC AXIS)
(M series)
Axes having different increment systems have been specified in the
same DI/DO group for PMC axis control. Modify the setting of parameter
No. 8010.
5066 RESTART ILLEGAL SEQUENCE
NUMBER
(M series)
Sequence number 7xxx has been read during search for the next se-
quence number at program restart for the return/restart function.
5068 G31 P90 FORMAT ERROR
(M series)
No movement axis or more than one movement axis has been speci-
fied.
5073 NO DECIMAL POINT No decimal point has been specified for an address requiring a decimal
point.
5074 ADDRESS DUPLICATION ERROR The same address has been specified two or more times in a single
block. Alternatively, two or more G codes in the same group have been
specified in a single block.
5082 DATA SERVER ERROR This alarm is detailed on the data server message screen.
NOTE
HPCC : High precision contour control
(2) Background edit alarm
Number Message Contents
??? BP/S alarm BP/S alarm occurs in the same number as the P/S alarm that occurs in
ordinary program edit. (070, 071, 072, 073, 074 085,086,087 etc.)
140 BP/S alarm It was attempted to select or delete in the background a program being
selected in the foreground. (Note)
Use background editing correctly.
NOTE
Alarm in background edit is displayed in the key input line of the background edit screen instead
of the ordinary alarm screen and is resettable by any of the MDI key operation.