B–62755EN/01
8.TROUBLESHOOTING
381
The digital servo module is not mounted.
CAUTION
This alarm may not occur during normal operaion.
This alarm may be generated when a PCB is changed for
maintenance.
Check installation of servo module on main CPU or option 2 board.
For location of servo module, refer to an installation diagram of alarm 920
and 922.
<Series 16/18 Main CPU board>
1st to 4th axis servo module
(A20B–2902–0070 or A20B–2902–0061)
<Option 2 board>
5th to 8th axis servo module
(A20B–2902–0070 or A20B–2902 –0061)
Unless these boards are mounted correctly, if this alarm still generates,
change main CPU board, option 2 board and/ or servo module.
A20B–2902–0070 Standard
A20B–2902–0061 For Learning control
8.34
ALARM 924 (SERVO
MODULE MOUNTING
ERROR)
D Causes and remedies
D Kinds of servo module