
B–62755EN/01
3. INPUT AND OUTPUT OF DATA
189
When custom macro function is equipped, values of variable no. 500 and
later are output.
1. Press
OFFSET
SETTING
key.
2. Press
key and soft key [MACRO] to select custom macro
variable screen.
3. Press soft key [(OPRT)] and then key
.
4. Press soft key [PUNCH] and [EXEC], then custom macro variable
values are output.
1. Select EDIT mode.
2. Press
OFFSET
SETTING
key and soft key [OFFSET] to display the tool
compensation amount screen.
3. Press [(OPRT)] key and soft key .
4. Press soft key [PUNCH] an [EXEC] key, and the tool compensation
amount is started to be output.
1. Confirm the following parameters. If 1 is set, set to the MDI mode and
set it to 0.
#7
3202
#6 #5 #4
NE9
#3 #2 #1 #0
NE8
#4 (NE9) l 0 : Programs of 9000s are edited.
1 : Programs of 9000s can be protected.
#0 (NE8) l 0 : Programs of 8000s are edited.
1 : Programs of 8000s can be protected.
2. Select EDIT mode.
3. Press PROG key and press soft key [PRGRM] to display program
text.
4. Press [(OPRT)] key and press soft key
.
5. Input a program number to be output. To output all programs input as:
O
–
9 9 9 9
6. Press [PUNCH] and [EXEC] key, then program output is started.
3.2.5
Outputting Custom
Macro Variable Values
3.2.6
Outputting Tool
Compensation Amount
3.2.7
Outputting Part Program