B–62755EN/01
1. DISPLAY AND OPERATION OF CRT/MDI
71
(4)Data number: The table below lists the numbers of the data items for
which a waveform can be displayed (n = 1 to 8).
Data No. Description Units
00 Does not display a waveform. –
0n Servo error (8 ms) for the n–th axis (positional devi-
ation)
Pulses
(detection units)
1n Pulse distribution for the n–th axis
(move command)
Pulses
(input increments)
2n Torque for the n–th axis (actual current) % (relative to maxi-
mum current)
3n Servo error (2 ms) for the n–th axis (positional devi-
ation)
Pulses
(detection units)
5n Actual speed for the n–th axis RPM
6n Command current for the n–th axis % (relative to maxi-
mum current)
7n Thermal simulation data for the n–th axis % (OVC alarm ratio)
90 Composite speed for the first, second, and third axes Pulses
(input increments)
99 On/off state of a machine signal specified with a sig-
nal address
None
10n Actual spindle speed for the n–th axis % (relative to maxi-
mum rotation speed)
11n Load meter for the spindle for the n–th axis % (relative to maxi-
mum output)
(5)Data units: Weight of data when 1 is specified. The data units are
automatically specified for each data item and need not be set unless
the units must be changed for some reason.
[Valid data range] 1 to 1000
[Unit] 0.001
(6)Signal address: PMC address and bit number. Set in the same way as
that for trigger, when the data number is 99.