B–62755EN/01
1. DISPLAY AND OPERATION OF CRT/MDI
63
0500 Send command
DGN
1: SYN 2: RDY 3: RST 4: ALM
5: SAT 6: GTD 7: RTY 8: SDI
0501 Receive command
DGN
1: SYN 2: RDY 3: ARS 4: AAL
5: CLB 6: SET 7: DAT 8: EOD
9: WAT 10: RTY 11:RDI 12: SDO
0502 State of remote buffer
DGN
0 : Not ready
1 : Reset state
2 : Operation state
3 : Alarm state
4 : Circuit disconnection
#7
510
#6 #5 #4 #3 #2 #1 #0
DGN
This data indicates the internal MMC–IV information (not available to
general users).
#7
511
#6 #5 #4 #3 #2 #1 #0
DGN
This data indicates the internal MMC–IV information (not available to
general users).
#7
PA1512
#6
PA0
#5
BNK
#4 #3
THH
#2
THL
#1 #0
PRA
DGN
This data indicates the cause of a system alarm that has occurred in
MMC–IV.
#0(PRA) 1 : A RAM parity error occurred in shared RAM.
#2(THL) 0 : The temperature of the MMC board is too low.
1 : Normal
#3(THH) 0 : The temperature of the MMC board is too high.
1 : Normal
#4 0 : Normal
1 : An NMI has occurred on the MMC board.
#5(BNK) If bit 0 (PRA) is set to 1,
0 : An alarm occurred in the lower half of shared RAM.
1 : An alarm occurred in the upper half of shared RAM.
#6 (PA0) If bit 0 (PRA) is set to 1,
1 : An alarm occurred at an even–numbered address.
#7 (PA1) If bit 0 (PRA) is set to 1,
1 : An alarm occurred at an odd–numbered address.
D State of remote buffer
(protocol A)
D Diagnostic data related
to MMC–IV