7. AC SPINDLE (ANALOG INTERFACE)
B–62755EN/01
288
Parameters can be set and confirmed
through the display and the setting switch
on the PCB.
PCB
Display
Setting
switch
Display
Setting
switch
1. If the PCB is mounted a jumper SH, set it to SET.
2. Press the setting switch
MODE
,
DATA
SET
,
⇑
UP
and
DOWN
⇓
at the
same time for more than 1 second and when the display shows FFFFF,
release the buttons.
3. Press the
MODE button and a parameter (mode) no. is displayed.
4. Press and hold the
MODE button and press the
⇑
UP
or
DOWN
⇓
button, then the number increases or decreases by 1.
5. Value of parameter is shown on the display in 4 digits about 0.5 second
after the
MODE button is released.
6. Value of parameter increases by one by
⇑
UP
button and decreases
by one by
DOWN
⇓
button.
7. Perform the same operation for another parameters.
8. Press
DATA
SET
button at last.
When the display shows 88888, the setting value is stored in memory.
* If you turn off power before pressing
DATA
SET
button, the values of
parameters return to the previous values.
7.3
SETTING
PARAMETERS
(DIGITAL AC
SPINDLE)