B–62755EN/01
1. DISPLAY AND OPERATION OF CRT/MDI
65
#7
530
#6 #5
A99
#4
A98
#3
A97
#2
A96
#1
A95
#0
A43
DGN
* Check the contents of this data if alarm 251 is output.
#5 (A99): A pry alarm occurred while the tool was being changed.
#4 (A98): After the power was turned on or after an emergency stop was released,
M06 was specified before the first reference position return. While the
tool was being changed, machine lock was enabled for the Z–axis.
#3 (A97): M06 is specified in canned cycle mode. M06 is specified in a block
containing the command instructing reference position return. M06 is
specified in tool compensation mode.
#2 (A96): The current tool number parameter (parameter No. 7810) is set to 0.
#1 (A95): M06 is specified while the Z–axis machine coordinate is positive.
#0 (A43): A prohibited T code is specified after M06.
#7
531
#6
585
#5
584
#4
583
#3
582
#2
581
#1
580
#0
502
DGN
#6 (585): Spindle servo alarm (excessive error during ATC magazine indexing)
#5 (584): Invalid sequence during positioning and ATC (system error)
#4 (583): Spindle servo alarm (LSI overflow)
#3 (582): Spindle servo alarm (excessive drift)
#2 (581): Spindle servo alarm (excessive error during travel)
#1 (580): Spindle servo alarm (excessive error in the stop state)
#0 (502): Large spindle distribution (system error)
Difference between position errors of the master axis and slave axis under simple
synchronous control
540
DGN
* M series only
The units are the same as the detection units.
D Diagnostic data related
to ATC for FD Alpha
D Diagnostic data related
to simple synchronous
control