B-65382EN/02 HANDLING, DESIGN, AND ASSEMBLY 3.ASSEMBLY
- 181 -
3.3.7 LiS 17000C2/2
Terminal and connector allocation
For thermostat. No polarity
applicable. (Pins 1 and 2)
Magnet plate
Power line, grounding, 2 locations
Power line, phase V, 2 locations
Power line, phase W, 2 locations
Power line, phase U, 2 locations
Pin No.
Cables usable for power lines
Model AWG
Nominal
cross-sectional area
(mm
2
)
Cable diameter
NOTE
LiS 17000C2/2 UL1015 AWG#10
5.5
or
6.0
φ4.9 to φ5.2
NOTE
1 If the diameter of a cable is not within the allowable range
specified above, the drip protection capability of the terminal is not
guaranteed. Be sure to select a cable that satisfies the diameter
range specified above.
2 Bend a power line outside the terminal. If a power line is bent
inside the terminal, the drip protection capability of the terminal is
not guaranteed.
3 When the coil slider is movable, be sure to use movable cables.
Do not attach a movable cable to each terminal, but attach a
movable cable to a relay terminal block in the middle.
Cable usable for the thermostat
AWG Nominal cross-sectional area (mm
2
) Cable diameter
NOTE
UL1015 AWG#23×2 0.3×2 φ4.6 to φ5.0
NOTE
1 If the diameter of a cable is not within the allowable range
specified above, the drip protection capability of the terminal is not
guaranteed. Be sure to select a cable that satisfies the diameter
range specified above.
2 When the coil slider is movable, be sure to use movable cables.