2.SPECIFICATIONS SPECIFICATIONS B-65382EN/02
- 6 -
2.1 TERMS USED IN THE SPECIFICATION LIST AND SPEED
DIAGRAMS
- Cooling method
There are the following methods for cooling a coil slider: No cooling,
air cooling, and water cooling.
- Maximum speed
Maximum speed of the motor. You can run the motor at up to this
speed.
- Upper speed for the maximum force
Upper limit of the speed at which the maximum force can be
maintained. If the speed exceeds this limit, the maximum force is
reduced.
- Continuous force
Force the motor can continuously output. How the coil slider
temperature rises depends on the material of the machine on which it
is mounted. When no cooling or air cooling is used, in particular, the
material affects the coil slider temperature. The specification list
contains the size of an aluminum heat sink on which each coil slider is
mounted.
Model
Size of the heat sink (mm)
Surface area of the coil slider × 2 × thickness
LiS 300A1
(73 × 71) × 2 × 20
LiS 600A1
(133 × 71) × 2 × 20
LiS 900A1
(193 × 71) × 2 × 20
LiS 1500B1
(297 × 130) × 2 × 50
LiS 3000B2
(297 × 200) × 2 × 50
LiS 4500B2
(417 × 200) × 2 × 50
LiS 6000B2
(537 × 200) × 2 × 50
LiS 7500B2
(657 × 200) × 2 × 50
LiS 9000B2
(777 × 200) × 2 × 50
LiS 3300C1
(417 × 150) × 2 × 50
LiS 9000C2
(537 × 260) × 2 × 50
LiS 11000C2
(657 × 260) × 2 × 50
LiS 15000C2
(897 × 260) × 2 × 50
LiS 10000C3
(417 × 355) × 2 × 50
LiS 17000C3
(657 × 355) × 2 × 50
- Maximum force
Maximum force the motor can generate when driven using the
standard amplifier. The maximum force can be used only in a short
time such as during acceleration or deceleration.
- Continuous current
Effective current per phase when the motor outputs the continuous
force. The peak value can be obtained by multiplying this value by
2 .