B-65382EN/02 SPECIFICATIONS 2.SPECIFICATIONS
- 7 -
- Maximum current
Effective current per phase when the motor outputs the maximum
force. The peak value can be obtained by multiplying this value by
2 .
- Continuous output/maximum output
Value obtained by converting the force (N) during motor operation to
the output (kW). For selection of a power supply module (PSM), see
Part II, "CONFIGURATIONS AND SELECTION."
- Maximum amplifier current
Maximum peak current of the standard amplifier. The effective value
can be obtained by dividing this value by
2 .
- Force constant
Force obtained when 1 Arms flows for one phase. The following
expression can be satisfied: [force constant] × [continuous current]
[continuous force]. This expression may not be satisfied due to
saturated magnetic force, however.
- Back electromotive force constant
Electromotive force per phase generated with the motor running at a
speed of 1 m/s that is indicated by the effective value. The voltage
between motor terminals can be obtained by multiplying this value
by
3 .
- Armature resistance
Resistance per phase of the coil slider at an ambient temperature of
25°C. The resistance between terminals is double this value.
- Thermal time constant
Thermal time constant for the coil slider
- Cooling conditions
Conditions for obtaining the rated output when forced cooling is used
- IC code:
Code indicating the cooling method that conforms to EN60034-6
- Coolant:
Primary coolant for directly cooling the coil slider
- Flow rate:
Required flow rate of the primary coolant
- Recommended pressure:
Recommended pressure for the primary coolant
- Maximum pressure:
Maximum pressure for the primary coolant
- Required cooling capacity:
Amount of heat absorbed that is required for obtaining the rated
output
- Magnetic attraction
Force of the magnetic attraction between the coil slider and magnet
plate
- Mass of the coil slider
Mass per coil slider
- Type of applicable magnet plate
Type of magnet plate that is applicable