B-65382EN/02 SPECIFICATIONS 2.SPECIFICATIONS
- 11 -
*1
Model
LiS 7500B2/2 LiS 9000B2/2 LiS 9000B2/4
Unit Symbol Item
No
cooling
Air
cooling
Water
cooling
No
cooling
Air
cooling
Water
cooling
No
cooling
Air
cooling
Water
cooling
- - Cooling method (*2)
2(4) 2 (4) 4 m/s - Maximum speed
1(2) 1 (2) 2 m/s -
Upper speed for the
maximum force
1500 1800 3000 1800 2160 3600 1800 2160 3600 N Fc Continuous force
7500 9000 9000 N Fp Maximum force
3.0
(6.0)
3.6
(7.2)
6.0
(12.0)
3.6
(7.2)
4.3
(8.6)
7.2
(14.4)
7.2 8.6 14.4 kW Pc Continuous output
8 (16)
(13.5)
9.6(20.3)
20.3
kW Pm Maximum output
11.6 13.9 23.2 13.9 16.7 27.8 22.7 36.8 61.3 Arms Ic Continuous current
71 85 170 Arms Ip Maximum current
160 (180) 160 (180) 360 Ap - Maximum amplifier current
129.4 129.4 58.7 N/Arms Kf Force constant
43.1 43.1 19.6 Vrms/(m/s) Ke
Back electromotive force
constant
0.865 0.74 0.185 Ω Ra Armature resistance
60 30 1 60 30 1 60 30 1 min. Tt Thermal time constant
0A8 9A7A7 9W7A7 0A8 9A7A7 9W7A7 0A8 9A7A7 9W7A7 - - IC code (*4)
- Air Water - Air Water - Air Water - - Coolant (*5)
- - 7.5 - - 7.5 - - 7.5 L/min - Flow rate
- - 0.42 - - 0.5 - - 0.5 MPa -
Recommended
pressure
- - 0.63 - - 0.63 - - 0.63 MPa -
Maximum
pressure
- - 1700 - - 2600 - - 2600 W -
Required
cooling
capacity
Cooling
conditions
(*3)
22500 27000 27000 N Fa Magnetic attraction (*6)
24.5 34 34 kg W Weight of the coil slider (*7)
B2 B2 B2 - -
Type of applicable magnet
plate (*8)
*1 Standard values at an ambient temperature of 25°C and a power supply voltage of 200 V
The values may vary depending on the ambient temperature, digital servo software, parameters, power supply voltage, amplifier specifications, and
others.
*2 When "no cooling" is used, the cooling tube in the coil slider is not used. To use "air cooling" or "water cooling," a forced cooling system using the
internal cooling tube is required.
*3 When "no cooling" or "air cooling" is used, the thermal loss differs depending on the materials of parts around the coil slider and machine configuration.
According to the thermal loss, the rating may vary.
*4 Conforms to EN60034-6. IC code "0A8" for "no cooling" is cooling for a movable coil slider. For cooling for a movable magnet plate, the IC code is
"0A0".
*5 Primary coolant for forced cooling (coolant for directly cooling the coil slider)
"Air" means ordinary industrial compressed air. "Water" means ion exchanged water (including 5% rust inhibitor).
*6 Maximum magnetic attraction between the coil slider and the magnet plate
The value varies depending on the size of the gap.
*7 When an incremental linear encoder is used, the weight of the magnetic pole sensor is added. For details, see the subsection "Magnetic Pole Sensor"
below.
*8 The type of applicable magnet plate differs depending on the motor model. For details, see the subsection "Magnet Plate" below.
*9 Can be driven by 400 V input (FANUC HV amplifier). The values in parentheses in the table indicate data when the motor is driven with 400 V. Drive
parameters dedicated to 400 V are required.