B-65272EN/04 FANUC AC SPINDLE MOTOR αiT SERIES 9.NOTES ON MOTOR INSTALLATION
- 205 -
9.7 ROTATION JOINT SUPPORT HOUSING
The machine tool builder is to prepare a rotation joint support housing.
To secure a housing, use a socket and spigot joint and six M5 tapped
holes at the motor rear end. Prepare six M5 bolts to secure a housing.
When a rotation joint of separate external support type is used,
coolant leaks from the sealing section (contact section between the
stationary side and rotation side). So, be sure to provide a drain on the
housing for the rotation joint. A drain of PT3/8 or more is required,
and a hose with an inner diameter of φ12 mm or more is required.
(To determine the final figure of a drain, be sure to contact the
manufacturer of a rotation joint.)
A housing of labyrinth structure for preventing coolant from
penetrating into the inside of the motor is required. Particularly when
the motor is oriented downward vertically, enhance drainage by
means such as air purging.
When the rotation joint is damaged, a large amount of coolant can
leak. So, provide many notches on the housing. Moreover, attach a
flow rate sensor to the drain to perform periodic flow rate
management. For details, refer to the specifications of each rotation
joint.
(Example of rotation joint support housing)
Taper section
Socket and spigot joint at
the motor rear end
When the motor is oriented downward vertically
6 M5 tapped holes
with a depth of 7
Air purge piping
Mounting housing
Coolant piping
Rotation joint
(separate type)
Drain
(Inner hose diameter of
φ
18 or more)
(PT3/8 or more)
Socket and spigot joint at
the motor rear end
Drain (notch)
Drain (spare)
(PT1/4)
When the motor is oriented horizontally
Notch (window)
Notch (window) on the mounting housing