4.NOTES ON INSTALLATION SPECIFICATIONS FOR THE αi SERIES B-65272EN/04
- 24 -
4.3 FAN MOTOR CONNECTION
50Hz 60Hz
α
αα
αi, α
αα
αiP, α
αα
αiT series
spindle motor models
Rated
voltage
[V]
Rated
current
[A]
Surge
current
[Ap-p]
Rated
voltage
[V]
Rated
current
[A]
Surge
current
[Ap-p]
α1i, α1.5i, α1.5iT
240 0.15 0.47 240 0.12 0.48
α2i, α3i, α2iT, α3iT
200 0.10 0.41 200 0.10 0.40
α6i, α8i, α6iT, α8iT
200 0.13 0.50 200 0.14 0.51
α12i to α22i,
α12i
P to α22iP,
α15i
T, α22iT
200 0.22 1.15 200 0.32 1.10
α30i, α40i,
α30i
P, α40iP, α50iP
200 0.65 3.12 200 0.8 3.06
α50i, α60i, α60iP
200 0.75 3.96 200 0.75 3.68
50Hz 60Hz
α
αα
α(HV)i, α
αα
α(HV)iP, α
αα
α(HV)iT series
spindle motor models
Rated
voltage
[V]
Rated
current
[A]
Surge
current
[Ap-p]
Rated
voltage
[V]
Rated
current
[A]
Surge
current
[Ap-p]
α1HVi, α1.5HVi, α1.5HViT
200 0.09 230 0.11
α2HVi, α3HVi,
α2HVi
T, α3HViT
200 0.11 230 0.13
α6HVi, α8HVi,
α6HVi
T, α8HViT
400 0.07 0.31 480 0.08 0.37
α12HVi to α22HVi,
α15HVi
P, α22HViP,
α15HVi
T, α22HViT
400 0.20 0.97 480 0.24 1.22
α30HVi, α40HVi,
α100HVi (circumference fan),
α40HVi
P, α50HViP
380 0.30 1.86 380 0.35 1.82
α60HVi, α60HViP
380 0.30 2.18 380 0.30 1.98
α100HVi (back fan)
400 0.30 400 0.36
NOTE
1 The term "surge current" represents a peak-to-peak
current that flows when the power is turned on.
2 The values listed below are a rough standard. They
are not guaranteed.