B-65272EN/04 SPECIFICATIONS FOR THE αi SERIES 4.NOTES ON INSTALLATION
- 31 -
4.6 WHEN A MOTOR IS DIRECTLY CONNECTED TO A
SPINDLE VIA A COUPLING
CAUTION
1 Use a coupling which can absorb thermal expansion in the axial
direction of the motor mating shaft so that no load is applied in
the motor axial direction.
(Examples)
- Diaphragm coupling (EAGLE INDUSTRY CO., LTD.)
- Oldham's coupling
- Gear coupling
2 Set the torsional rigidity of the coupling to an appropriate high
value. If the torsional rigidity is low, vibration may be produced
during orientation.
3 It is important to perform centering and obtain parallelism to
avoid having to recourse to the flexibility of the coupling.
At high speeds, any eccentricity may cause the bearing to fail
prematurely.
4 Check all machines before shipping to confirm that the vibration
acceleration is 0.5 G or less when measured using the method
described in CAUTION 4 of Section 4.1.