B-65272EN/04 SPECIFICATIONS FOR THE αi SERIES 4.NOTES ON INSTALLATION
- 21 -
4. How to connect power leads to output switching type motors
For output switching type motors, six power leads (the U-, V-,
W-, X-, Y-, and Z-phase wires) can be connected on the terminal
board.
Te r m i n a l b oa r d
Screws (six M5 screws)
V
U
W
Z
Y
Cover
•
••
• Detailed descriptions of an
M5 type terminal board
The terminal board has two
rows. The U-, V-, and W-phase
leads can be connected to the
upper row, while the Z-, X-, and
Y-phase wires can be
connected to the lower row.
1) Using the motor by switching its output
To use the motor by switching its output, connect the six
power leads (the U-, V-, W-, X-, Y-, and Z-phase wires)
respectively to the terminal board screws marked U, V, W,
X, Y, and Z.
(For the α15/12000i
T and αiL series motors, the terminal
board screws are marked U
1
, V
1
, W
1
, U
2
, V
2
, and W
2
.)
•
••
• Connecting power wires to
an M5 type terminal board
<1> Connecting power leads to
the lower row
Attach the Z-, X-, and Y-
phase power leads to the
lower row and fasten them
with the screws.
Power lead
Z
Y
<2> Attaching power leads to
the upper row
After putting the cover on
the lower row, attach the
U-, V-, and W-phase power
leads to the upper row and
fasten them with the
V
U
W
Cover