5.CONNECTIONS FANUC AC SPINDLE MOTOR α(HV)iT SERIES B-65272EN/04
- 336 -
5.3 CONNECTION OF SIGNAL LEAD
MZi sensor signal or overheat signal use a connector manufactured by
Tyco Electronics AMP .
The connector housing and the connector are attached to the motor.
Connector pins arrangement
Number
B1 B2 B3 B4 B5 B6
Color
Signal
*VA *VB *VZ 0V THR2
Number
A1 A2 A3 A4 A5 A6
Color
Signal
+5V VA VB VZ SS THR1
Connector housing and contact specifications
Connector and contact :
Tyco Electronics AMP specification D-3000 series
Motor side Cable side
FANUC specification
Manufacture
specification
FANUC specification
Manufacture
specification
Housing A63L-0001-0535/121KDF 178964-6 A63L-0001-0460/121KD 178289-6
Contact A63L-0001-0456/ASMT 175288-2 A63L-0001-0456/ASM 1-175217-2
Crimping tool : 91559-1 Extractor : 234168-1
Thermistor specification
Signal THR1 corresponds to one of the thermistor terminals, and
signal THR2, to the other terminal. The resistance of the thermistor is
about 30 to 90 kΩ as measured at room temperature (20°C to 30°C).
THR1
THR2
+5V
0V
VA
*VA
VB
*VB
VZ
*VZ
SS