B-65272EN/04 FANUC AC SPINDLE MOTOR α(HV)i SERIES 2.SPECIFICATIONS
- 237 -
(*1) For α100/4000HVi, the CNC soft option and switching
magnetic contactor unit associated with the output switch
function (Y-∆ switch) are required.
See FANUC SERVO AMPLIFIER αi series DESCRIPTIONS
(B-65282EN) for details of the output switch control.
(*2) The rated output is guaranteed at the rated voltage.
(Amplifier input:
α100/4000HVi : 460/480VAC +10% -0%, 50/60 Hz ±1Hz
Models except α100/4000HVi : 400/480VAC +10% -15%,
50/60 Hz ±1Hz)
If the input voltage fluctuates, it is possible that the rated output
cannot be obtained even when such fluctuations are within the
allowable fluctuation range.
(*3) The output for α0.5/10000HVi, α1/10000HVi, or
α2/10000HVi is 15 min rated. That for α1.5/10000HVi is 10
min rated.
(*4) S3 40% for α0.5/10000HVi or α30/6000HVi, S3 25% for
α1.5/10000HVi.
(*5) The cycle time is 10 minutes, S3 60%: ON 6 minutes, OFF 4
minutes, S3 40%: ON 4 minutes, OFF 6 minutes and S3 25%:
ON 2.5 minutes, OFF 7.5 minutes.
(*6) The rated current is not a guaranteed value but a guideline for
the maximum current at rated output.
(*7) IC code conforms to IEC 34-6.
(*8) IM code conforms to IEC 34-7.
(*9) This is not a guaranteed value but a guideline for the maximum
motor output at a rated supply voltage. 120% of 15 min rated
for α0.5/10000HVi, α1/10000HVi, or α2/10000HVi , 120%
of 10 min rated for α1.5/10000i, and 120% of continuous rated
for α100/4000HVi.
(*10) Type conforms to IEC 34-11.
(*11) These values are to be used only as guidance for selecting a
power supply module and are not guaranteed.
(*12) Degree of protection: with oil seal:IP54, without oil seal:IP40.
Degree of protection (α100/4000HVi): with oil seal:IP40.
(*13) Input power supply voltage of a fan motor for α1/10000HVi,
α1.5/10000HVi, α2/10000HVi, or α3/10000HVi is
200/230VAC +10% -15%, 50/60 Hz ±1Hz.