B-65272EN/04 SPECIFICATIONS FOR THE αi SERIES 7.DETERMINING THE ALLOWABLE DUTY CYCLE
- 39 -
7 DETERMINING THE ALLOWABLE DUTY
CYCLE
When machining requires the spindle to accelerate and decelerate
frequently, the average output per cycle must not exceed the
continuous rated output.The allowable duty cycle for a typical AC
spindle motor can be obtained as shown below.
Duty cycle and average output
Motor
speed
t1 t2 t3 t4
P
1
P
2
P
3
P
4
t5
One cycle time Dt
P
1
Motor
output
P
1
, P
4
: Acceleration/deceleration output [kW]
= 30 min rated output at const. output power range × 1.2
Note 1) 10 min rated output at const. output power range ×
1.2 or 15 min rated output at const. output power
range × 1.2 apply for some models.
Note 2) This is not a guaranteed value but a guideline.
P
2
: Output with no load [kW] (P
2
=0)
P
3
: Cutting output [kW]
t
D
tttt 4P3P2P1P
Pavoutput Average
2
4
2
3
2
2
2
1
+++
=
NOTE This is not a guaranteed value but a guideline.